Используя надежные, инновационные ASD (Application Specific Devices) технологии, устройства компании ST ACS ™ и ACST – это специфические переключатели, разработанные для бытовой техники и промышленных приложений и управления. При сохранении возможности отключения устройства при наличии логического уровня с помощью микроконтроллера. Со встроенной защитой от перенапряжения и против случайных переходных процессов.

Part Number |
General Description |
Package |
RMS on-state current (A) |
Repetitive peak off-state voltage (V) |
Non repetitive surge peak on-state current (A) |
Junction Temperature (°C) |
Quadrants |
Triggering gate current max (mA) (II, III) |
Clamping Voltage (V) (@1mA) |
Rate of decrease of commutating on-state current (A/ms) (@Tj max) |
Rising Ratio Of Off Voltage (V/µs) (@Tj max) |
Marketing Status |
ACS102-6T |
Overvoltage protected AC switch |
SO-8;TO-92 |
0.2 |
600 |
7.3 |
125 |
II, III |
5-5 |
650 |
0.15 |
300 |
Active |
ACS108 |
Overvoltage protected AC switch |
SOT-223;TO-92 |
0.8 |
600;800 |
13.7 |
125 |
II, III |
10-10 |
650;850 |
2 |
400 |
Active |
ACS108-6S |
Overvoltage protected AC switch |
SMBflat-3L |
0.8 |
600 |
7.3 |
125 |
II, III |
10-10 |
650 |
0.3 |
500 |
NRND |
ACS108-8SUN |
Overvoltage protected AC switch |
SMBflat-3L |
0.8 |
800 |
13 |
125 |
II, III |
10, 10 |
850 |
0.2 |
400 |
Active |
ACS108-8TN |
Overvoltage protected AC switch (ACS™) |
SOT-223 |
0.8 |
800 |
13 |
125 |
II, III |
5, 5 |
850 |
0.8 |
300 |
Active |
ACS110 |
Overvoltage protected AC switch |
SOT-223 |
1 |
700 |
8 |
125 |
II, III |
10-10 |
750 |
0.5 |
500 |
Active |
ACS120 |
Overvoltage protected AC switch |
DPAK;TO-220AB;TO-220FPAB |
2 |
700 |
20 |
125 |
II, III |
10-10 |
750 |
1 |
500 |
Active |
ACS302 |
Overvoltage protected triple AC switch array |
SO-20 |
0.2 |
500 |
7.3 |
125 |
II, III |
5-5 |
600 |
0.15 |
300 |
Active |
Part Number |
General Description |
Package |
RMS on-state current (A) |
Repetitive peak off-state voltage (V) |
Non repetitive surge peak on-state current (A) |
Junction Temperature (°C) |
Quadrants |
Triggering gate current max (mA) (I, II, III) |
Clamping Voltage (V) (@100µA) |
Rate of decrease of commutating on-state current (A/ms) (@Tj max) |
Rising Ratio Of Off Voltage (V/µs) (@Tj max) |
Marketing Status |
ACST10 |
Overvoltage protected AC switch |
TO-220AB;TO-220FPAB |
10 |
700 |
100 |
125 |
I, II, III |
10-10-10;35-35-35 |
850 |
12;4.4 |
200;2000 |
Active |
ACST1035-8FP |
Overvoltage protected 10 A 800 V AC switch |
TO-220FPAB |
10 |
800 |
100 |
150 |
I, II, III |
35-35-35 |
850 |
5 |
2000 |
Active |
ACST12 |
Overvoltage protected AC switch |
D2PAK;TO-220AB |
12 |
700 |
120 |
125 |
I, II, III |
10-10-10;35-35-35 |
850 |
14;5.3 |
200;2000 |
Active |
ACST1235-8FP |
Overvoltage protected AC switch |
TO-220FPAB |
12 |
800 |
100 |
150 |
I, II, III |
35-35-35 |
850 |
5 |
2000 |
Active |
ACST1635-8FP |
Overvoltage protected AC switch |
TO-220FPAB |
16 |
800 |
140 |
150 |
I, II, III |
35-35-35 |
850 |
4 |
300 |
Active |
ACST2 |
Overvoltage protected AC switch |
DPAK;TO-220FPAB |
2 |
800 |
8 |
125 |
I, II, III |
10-10-10 |
850 |
0.5 |
500 |
Active |
ACST310-8FP |
Overvoltage protected AC switch |
TO-220FPAB |
3 |
800 |
20 |
125 |
I, II, III |
10 |
850 |
5 |
1000 |
Active |
ACST4 |
Overvoltage protected AC switch |
DPAK;TO-220FPAB |
4 |
800 |
30 |
125 |
I, II, III |
10-10-10;35-35-35 |
850 |
2;5 |
1000;500 |
Active |
ACST6 |
Overvoltage protected AC switch |
D2PAK;TO-220AB;TO-220FPAB |
6 |
800 |
45 |
125 |
I, II, III |
10-10-10 |
850 |
3.5 |
500 |
Active |
ACST8 |
Overvoltage protected AC switch |
D2PAK;TO-220AB;TO-220FPAB |
8 |
800 |
80 |
125 |
I, II, III |
30-30-30 |
850 |
8 |
2000 |
Active |